Nec adipiscing luctus consequat penatibus parturient massa cubilia etiam.

ActiV Conventional O-R-3-2.5-17 Base VAD c/w 96dB(A) Sounder

£32.93

  • Third-party certified to EN54-3 (Sounders) and EN54-23 (VADs).
  • Provides ‘O-R-3-2.5-17’ light distribution.
  • Ideally suited for use in corridors and other rectangular areas.
  • Impressive 96dB(A) sound output @ 1m.
  • 31 selectable primary and secondary tone pairs and two volume levels (high and low)
  • Three selectable VAD flash rates (0.5Hz, 1Hz, OFF)
  • Alarm Current at 30Vdc = 12.2mA (0.5Hz) or 19.5mA (1Hz)
  • Alarm Current at 18Vdc = 14.5mA (0.5Hz) or 25mA (1Hz)
  • Optional BF330CTLIDW white or BF330CTLIDR red cap available for stand-alone use.
  • Supplied with a BF431QCP quick connect plate and detector spur wires.
  • IP21C rated.

LPCB

SKU: BF432C/CC/W Category: Tags: , , ,

Description

Approvals/certifications Certified to EN54-3 & 23 by the LPCB.
Protocol/compatibility Compatible with C-TEC’s CFP, FP, MFP and EP203 conventional fire alarm panels and virtually all other makes (testing on third-party panels is recommended before use)
Application/operation Designed to be ceiling mounted – either stand-alone with a red or white cap or as part of a stacked Sounder/VAD/Detector Base combination.
VAD category & coverage O-R-3-2.5-17 Rectangular coverage – ideal for corridor spaces.
Flash rate & colour 0.5Hz; 1Hz or OFF / White.
Supply/operating voltage 18 to 30V DC.
Nominal SPL (Sound Pressure Level) 96dB(A).
Alarm current At 30Vdc: 12.2mA (0.5Hz) or 19.5mA (1Hz); At 18Vdc: 14.5mA (0.5Hz) or 25mA (1Hz)
Product dimensions (mm) 122mm diameter x 46mm deep (not including optional detector and base).
IP Rating IP21C (Type A).
Weight 170g.
Operating conditions/temperature -10ºC to +55ºC. Max. 95% RH (Non-condensing).
Notes For compliance to EN 54-3 & EN54-23, the BF431QCP Quick Connect Plate must be used with the base device.

 

VAD coverage depends on factors such as ambient light and viewing angle (direct or indirect). The table below summarises how the coverage of the BF432C/CC/W increases or decreases based on these factors. To use the table, calculate the lux level of the area requiring coverage, determine whether the viewing angle will be direct or indirect then read off the coverage in the relevant column. For further information refer to our VAD System Design Guide, downloadable from the Documentation tab below.

Lux level in area requiring coverage Ceiling Mounted Direct Viewing Ceiling Mounted Indirect Viewing
000-101 lux 8.4m H x 7.0m W x 47.6m L 3.9m H x 3.25m W x 22.1m L
101-200 lux 7.2m H x 6.0m W x 40.8m L 3.6m H x 3.0m W x 20.4m L
201-300 lux 5.7m H x 4.5m W x 32.3m L 3.0m H x 2.5m W x 17.0m L
301-400 lux 4.2m H x 3.5m W x 23.8m L 2.4m H x 2.0m W x 13.6m L
401-500 lux 3.3m H x 2.7m W x 18.7m L 1.8m H x 1.5m W x 10.2m L
501-600 lux 2.7m H x 2.2m W x 15.3m L 1.5m H x 1.2 W x 8.5m L
601-700 lux 2.1m H x 1.7m W x 11.9 L not applicable
701-800 lux 1.5m H x 1.2 W x 8.5m L not applicable