SAP 1 Loop 16 Zone Addressable Sprinkler Monitoring Panel (C-TEC CAST protocol)

£619.40

  • Ideal for monitoring up to 255 sprinkler flow switches.
  • One CAST CA730 input output unit required per monitored flow switch.
  • Utilises the same technology as C-TEC’s popular XFP addressable fire panel.
  • Up to 16 sprinkler zone indicators available (assignable via the panel’s PC programming tools).
  • Attractive flush or surface mountable plastic enclosure.
  • Combined keypad or keyswitch entry.
SKU: SAP501E/CA Category: Tags: , ,

Description

Protocol/compatibility C-TEC CAST.
Mains supply 230V 50/60Hz.
Mains rated current 350mA maximum.
Internal power supply 27Vdc nominal.
Total output current limited to 1.4A @ 230Vac (Imax.A 210mA; Imin. 40mA).
Quiescent current 50mA (loop unloaded).
Max battery size and type 2 x 12V 3.2Ah VRLA connected in series.
No. of loop drivers 1.
Max. loop output current 500mA (40V max).
Max. loop length 1KM.
Max. addressable devices per loop 255.
No. of conventional sounder circuits 2 (Max. length per circuit is 500m).
EOL resistor value 6800Ω 5% Tol. 0/25W (blue, grey, red, gold).
Max. sounder output current 400mA.
Auxiliary relays 3 x Programmable Relays (programmable from C&Es). 1 x Fault Relay (active when no faults are present). Volt free single pole changeover. Max. switch current 1A; Max. switch voltage 30Vdc.
Other outputs 24V Aux. Power (19.5V min, 28V max). Protected by a resettable fuse. Max. current 100mA.
Auxiliary inputs 2 x Programmable Inputs (programmable from C&Es). Connect to 0V to trigger, Max. input voltage 27V (non-latching).
PC connection PC connection via RS232 molex connector (supplied in XFP507 upload/download software kit); No printer connection available.
Indicators 2 line x 40 character backlit display; 16 Zonal LEDs, General Fire; Energised; Pre-Alarm; Remote Output Activated; Remote Output Disabled; Accessed; Disablement; Test; Silenced; General Fault; System Fault.
Connections Fixed, largest acceptable conductor size 1mm2.
Expansion connections 2-wire RS485 non-redundant network/repeater connection available via optional XFP761 network card. Max. 8 mains per network or 8 repeaters per non-networked main. Limit 1KM (main panel network) or 500M (repeater network).
Product dimensions (mm) 380 W x 235 H x D 96mm;
Construction & finish Plastic lid and base; RAL7035 textured.
IP Rating IP30.
Weight 1.8kg (without batteries).
Operating conditions/temperature -5ºC to +40ºC. Max relative humidity: 95%.