Mains supply |
230V 50/60Hz. |
Mains rated current |
350mA maximum. |
Internal power supply |
27Vdc nominal. |
Total output current limited to |
3A @ 230Vac. |
Quiescent current |
100mA @ 24V |
Max battery size and type |
2 x 12V 7Ah VRLA connected in series. |
Cabling |
Spine & limb arrangement using QT603 network splitters. Spines wired in 1.5-2.5mm2 T&E; Limbs wired in 4 core stranded security cable (up to 6 limbs per QT603 splitter). Refer to main instructions for more details. |
Open collector outputs |
OP1 (active on standard call); OP2 (active on help req. call); OP3 (active on emergency call); OP4 (active on attack call). OP5 (failsafe fault output). Voltfree single pole c/o. Max. switch current 25mA; Max. switch voltage 30Vdc. |
Other outputs |
24V Aux. Power (19.5V min, 28V max). Protected by a resettable fuse. Max. current 100mA. |
PC connection |
CONN1 provides an RS232 connection for use with our Quantec Surveyor data management software (via a PC) or a Quantec Printer. |
Indicators |
2 line x 40 character backlit display; Power LED (lit when power is present, off when no power present). |
Controls |
Accept (A); Scroll Up; Scroll Down; Code Entry Buttons (1, 2, 3 and 4); Escape (E). |
Connections |
Plug-on type, largest acceptable conductor size 1mm2. |
Expansion connections |
CONN2 provides an RS232 connection for paging equipment. |
Product dimensions (mm) |
410 W x 250 H x 80 D mm (base); 439 W x 274 H x 7 D mm (lid). |
Construction & finish |
Metal base, plastic lid. |
IP Rating |
IP30 |
Weight |
3.5Kg. |
Operating conditions/temperature |
-5ºC to +40ºC. Max relative humidity: 95%. |